Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-head-circumference vs http://hl7.org/fhir/us/pacio-fp/StructureDefinition/fp-observation

Left:US Core Head Circumference Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-head-circumference)
Right:Functional Performance Observation (http://hl7.org/fhir/us/pacio-fp/StructureDefinition/fp-observation)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-head-circumference' vs 'http://hl7.org/fhir/us/pacio-fp/StructureDefinition/fp-observation'
ErrorStructureDefinition.versionValues for version differ: '5.0.0' vs '1.0.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreHeadCircumferenceProfile' vs 'FunctionalPerformanceObservation'
InformationStructureDefinition.titleValues for title differ: 'US Core Head Circumference Profile' vs 'Functional Performance Observation'
InformationStructureDefinition.dateValues for date differ: '2022-04-20' vs '2022-05-13T16:07:55-04:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 Patient Care Work Group'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'US Core Head Circumference Profile' vs 'Measurements and simple assertions'
WarningObservationElements differ in definition: '\-' vs 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservationElements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
WarningObservation.extensionElements differ in short: 'Additional content defined by implementations' vs 'Extension'
WarningObservation.extensionElements differ in definition: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' vs 'An Extension'
WarningObservation.basedOnElements differ in short: 'Fulfills plan, proposal or order' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.partOfElements differ in short: 'Part of referenced event' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.statusElements differ in short: 'registered | preliminary | final | amended +' vs 'Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.'
WarningObservation.statusElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.categoryElements differ in short: 'Classification of type of observation' vs 'A second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code.'
WarningObservation.codeElements differ in short: 'Head Circumference' vs 'For a Post-Acute Care Assessment, should include a LOINC code and text for the question or concept name.'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.codeElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.subjectElements differ in short: 'Who and/or what the observation is about' vs 'Should only reference a Patient resource.'
WarningObservation.subjectElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.focusElements differ in short: 'What the observation is about, when it is not about the subject of record' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
WarningObservation.effective[x]Elements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.issuedElements differ in short: 'Date/Time this version was made available' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.performerElements differ in short: 'Who is responsible for the observation' vs 'The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization.'
InformationObservation.performerElement minimum cardinalities differ: '0' vs '1'
WarningObservation.value[x]Elements differ in short: 'Vital Signs Value' vs 'Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension.'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.interpretationElements differ in short: 'High, low, normal, etc.' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.bodySiteElements differ in short: 'Observed body part' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.methodElements differ in short: 'How it was done' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.specimenElements differ in short: 'Specimen used for this observation' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.deviceElements differ in short: '(Measurement) Device' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.referenceRangeElements differ in short: 'Provides guide for interpretation' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' vs 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
WarningObservation.derivedFromElements differ in short: 'Related measurements the observation is made from' vs 'Should point back to the SDC QuestionnaireResponse that this resource is derived from.'
WarningObservation.derivedFromElements differ in definition for mustSupport: 'false' vs 'true'
ErrorObservation.derivedFromType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaireresponse]])
WarningObservation.componentElements differ in short: 'Component observations' vs 'Currently not used in FunctionalPerformanceObservation.'
WarningObservation.componentElements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
WarningObservation.componentElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Component Value' vs 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.component.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2022-04-202022-05-13T16:07:55-04:00
    • Values Differ
    .descriptionTo promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch head circumference observations with a standard LOINC code and UCUM units of measure. It is based on the US Core Vital Signs Profile and identifies the *additional* mandatory core elements, extensions, vocabularies and value sets which **SHALL** be present in the Observation resource when using this profile. It provides the floor for standards development for specific uses cases.An exchange of post-acute care observation for a patient. This profile is used for exchanging a single observation data generally included in a set of observation data collected through the use of a structured resource (e.g. assessment tool, instrument, or screen).
    • Values Differ
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCoreHeadCircumferenceProfileFunctionalPerformanceObservation
            • Values Differ
            .publisherHL7 International - Cross-Group ProjectsHL7 Patient Care Work Group
            • Values Differ
            .purpose
              .statusactive
                .titleUS Core Head Circumference ProfileFunctional Performance Observation
                • Values Differ
                .typeObservation
                  .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-head-circumferencehttp://hl7.org/fhir/us/pacio-fp/StructureDefinition/fp-observation
                  • Values Differ
                  .version5.0.01.0.0
                  • Values Differ

                  Structure

                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                  .. Observation I0..*USCoreVitalSignsProfileUS Core Head Circumference Profile
                  I0..*ObservationMeasurements and simple assertions
                  • Elements differ in short: 'US Core Head Circumference Profile' vs 'Measurements and simple assertions'
                  • Elements differ in definition: '\-' vs 'Measurements and simple assertions made about a patient, device or other subject.'
                  • Elements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
                  ... id Σ0..1stringLogical id of this artifactΣ0..1stringLogical id of this artifact
                    ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                      ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                        ... language 0..1codeLanguage of the resource content
                        Binding: CommonLanguages (preferred): A human language.

                        Additional BindingsPurpose
                        AllLanguagesMax Binding
                        0..1codeLanguage of the resource content
                        Binding: CommonLanguages (preferred): A human language.

                        Additional BindingsPurpose
                        AllLanguagesMax Binding
                          ... text 0..1NarrativeText summary of the resource, for human interpretation0..1NarrativeText summary of the resource, for human interpretation
                            ... contained 0..*ResourceContained, inline Resources
                            0..*ResourceContained, inline Resources
                              ... extension 0..*ExtensionAdditional content defined by implementations
                              0..*ExtensionExtension
                              Slice: Unordered, Open by value:url
                              • Elements differ in short: 'Additional content defined by implementations' vs 'Extension'
                              • Elements differ in definition: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' vs 'An Extension'
                              ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                              ?!0..*ExtensionExtensions that cannot be ignored
                                ... identifier Σ0..*IdentifierBusiness Identifier for observation
                                Σ0..*IdentifierBusiness Identifier for observation
                                  ... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                  Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Currently not used in FunctionalPerformanceObservation.
                                  • Elements differ in short: 'Fulfills plan, proposal or order' vs 'Currently not used in FunctionalPerformanceObservation.'
                                  ... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                  Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Currently not used in FunctionalPerformanceObservation.
                                  • Elements differ in short: 'Part of referenced event' vs 'Currently not used in FunctionalPerformanceObservation.'
                                  ... status ?!SΣ1..1coderegistered | preliminary | final | amended +
                                  Binding: ObservationStatus (required)
                                  ?!Σ1..1codeShould have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.
                                  Binding: ObservationStatus (required): Codes providing the status of an observation.

                                  • Elements differ in short: 'registered | preliminary | final | amended +' vs 'Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.'
                                  • Elements differ in definition for mustSupport: 'true' vs 'false'
                                  ... Slices for category S1..*CodeableConceptClassification of type of observation
                                  Slice: Unordered, Open by value:coding.code, value:coding.system
                                  Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


                                  S1..*CodeableConceptA second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code.
                                  Slice: Ordered, Open by pattern:coding
                                  Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


                                  • Elements differ in short: 'Classification of type of observation' vs 'A second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code.'
                                  ... code SΣ1..1CodeableConceptHead Circumference
                                  Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.


                                  Required Pattern: {"coding":[{"system":"http://loinc.org","code":"9843-4"}]}
                                  Σ1..1CodeableConceptFor a Post-Acute Care Assessment, should include a LOINC code and text for the question or concept name.
                                  Binding: Functional Performance ValueSet LOINC SNOMED (extensible)
                                  • Elements differ in short: 'Head Circumference' vs 'For a Post-Acute Care Assessment, should include a LOINC code and text for the question or concept name.'
                                  • Elements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation "name".'
                                  • Elements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
                                  • Elements differ in definition for mustSupport: 'true' vs 'false'
                                  ... subject SΣ1..1Reference(US Core Patient Profile)Who and/or what the observation is aboutΣ1..1Reference(US Core Patient Profile)Should only reference a Patient resource.
                                  • Elements differ in short: 'Who and/or what the observation is about' vs 'Should only reference a Patient resource.'
                                  • Elements differ in definition for mustSupport: 'true' vs 'false'
                                  ... focus Σ0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                  Σ0..*Reference(Resource)Currently not used in FunctionalPerformanceObservation.
                                  • Elements differ in short: 'What the observation is about, when it is not about the subject of record' vs 'Currently not used in FunctionalPerformanceObservation.'
                                  ... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is madeΣ0..1Reference(US Core Encounter Profile)Healthcare event during which this observation is made
                                    ... effective[x] SΣI1..1dateTime S, PeriodOften just a dateTime for Vital SignsΣ1..1dateTimeClinically relevant time/time-period for observation
                                    • Elements differ in short: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
                                    • Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
                                    • Elements differ in definition for mustSupport: 'true' vs 'false'
                                    ... issued Σ0..1instantDate/Time this version was made availableΣ0..1instantCurrently not used in FunctionalPerformanceObservation.
                                    • Elements differ in short: 'Date/Time this version was made available' vs 'Currently not used in FunctionalPerformanceObservation.'
                                    ... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                    Σ1..*Reference(US Core Practitioner Profile | US Core PractitionerRole Profile | US Core Organization Profile)The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization.
                                    • Elements differ in short: 'Who is responsible for the observation' vs 'The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization.'
                                    • Element minimum cardinalities differ: '0' vs '1'
                                    ... Slices for value[x] SΣI0..1QuantityVital Signs Value
                                    Slice: Unordered, Closed by type:$this
                                    Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

                                    ΣI0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodWhenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension.
                                    • Elements differ in short: 'Vital Signs Value' vs 'Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension.'
                                    • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                    • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                    • Elements differ in definition for mustSupport: 'true' vs 'false'
                                    ... dataAbsentReason SI0..1CodeableConceptWhy the result is missing
                                    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                    I0..1CodeableConceptWhy the result is missing
                                    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                    • Elements differ in definition for mustSupport: 'true' vs 'false'
                                    ... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                    Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                    0..*CodeableConceptCurrently not used in FunctionalPerformanceObservation.
                                    Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                    • Elements differ in short: 'High, low, normal, etc.' vs 'Currently not used in FunctionalPerformanceObservation.'
                                    ... note 0..*AnnotationComments about the observation
                                    0..*AnnotationComments about the observation
                                      ... bodySite 0..1CodeableConceptObserved body part
                                      Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

                                      0..1CodeableConceptCurrently not used in FunctionalPerformanceObservation.
                                      Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

                                      • Elements differ in short: 'Observed body part' vs 'Currently not used in FunctionalPerformanceObservation.'
                                      ... method 0..1CodeableConceptHow it was done
                                      Binding: ObservationMethods (example): Methods for simple observations.

                                      0..1CodeableConceptCurrently not used in FunctionalPerformanceObservation.
                                      Binding: ObservationMethods (example): Methods for simple observations.

                                      • Elements differ in short: 'How it was done' vs 'Currently not used in FunctionalPerformanceObservation.'
                                      ... specimen 0..1Reference(Specimen)Specimen used for this observation0..1Reference(Specimen)Currently not used in FunctionalPerformanceObservation.
                                      • Elements differ in short: 'Specimen used for this observation' vs 'Currently not used in FunctionalPerformanceObservation.'
                                      ... device 0..1Reference(Device | DeviceMetric)(Measurement) Device0..1Reference(Device | DeviceMetric)Currently not used in FunctionalPerformanceObservation.
                                      • Elements differ in short: '(Measurement) Device' vs 'Currently not used in FunctionalPerformanceObservation.'
                                      ... referenceRange I0..*BackboneElementProvides guide for interpretation
                                      I0..*BackboneElementCurrently not used in FunctionalPerformanceObservation.
                                      • Elements differ in short: 'Provides guide for interpretation' vs 'Currently not used in FunctionalPerformanceObservation.'
                                      .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                        .... extension 0..*ExtensionAdditional content defined by implementations
                                        0..*ExtensionAdditional content defined by implementations
                                          .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                          ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                            .... low I0..1SimpleQuantityLow Range, if relevantI0..1SimpleQuantityLow Range, if relevant
                                              .... high I0..1SimpleQuantityHigh Range, if relevantI0..1SimpleQuantityHigh Range, if relevant
                                                .... type 0..1CodeableConceptReference range qualifier
                                                Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

                                                0..1CodeableConceptReference range qualifier
                                                Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

                                                  .... appliesTo 0..*CodeableConceptReference range population
                                                  Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


                                                  0..*CodeableConceptReference range population
                                                  Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


                                                    .... age 0..1RangeApplicable age range, if relevant0..1RangeApplicable age range, if relevant
                                                      .... text 0..1stringText based reference range in an observation0..1stringText based reference range in an observation
                                                        ... hasMember Σ0..*Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Used when reporting vital signs panel components
                                                        Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Currently not used in FunctionalPerformanceObservation.
                                                        • Elements differ in short: 'Used when reporting vital signs panel components' vs 'Currently not used in FunctionalPerformanceObservation.'
                                                        • Elements differ in definition: 'Used when reporting vital signs panel components.' vs 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
                                                        • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                        ... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
                                                        SΣ0..*Reference(SDC Questionnaire Response)Should point back to the SDC QuestionnaireResponse that this resource is derived from.
                                                        • Elements differ in short: 'Related measurements the observation is made from' vs 'Should point back to the SDC QuestionnaireResponse that this resource is derived from.'
                                                        • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                        • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaireresponse]])
                                                        ... component SΣI0..*BackboneElementComponent observations
                                                        Σ0..*BackboneElementCurrently not used in FunctionalPerformanceObservation.
                                                        • Elements differ in short: 'Component observations' vs 'Currently not used in FunctionalPerformanceObservation.'
                                                        • Elements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
                                                        • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                        .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                          .... extension 0..*ExtensionAdditional content defined by implementations
                                                          0..*ExtensionAdditional content defined by implementations
                                                            .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                            ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                              .... code SΣ1..1CodeableConceptType of component observation (code / type)
                                                              Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.

                                                              Σ1..1CodeableConceptType of component observation (code / type)
                                                              Binding: LOINCCodes (example): Codes identifying names of simple observations.

                                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                              • Elements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
                                                              .... value[x] SΣI0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Sign Component Value
                                                              Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

                                                              Σ0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual component result
                                                              • Elements differ in short: 'Vital Sign Component Value' vs 'Actual component result'
                                                              • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                                              • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                              .... dataAbsentReason SI0..1CodeableConceptWhy the component result is missing
                                                              Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                              I0..1CodeableConceptWhy the component result is missing
                                                              Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                              .... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                              Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                                              0..*CodeableConceptHigh, low, normal, etc.
                                                              Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                                                .... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
                                                                0..*See referenceRange (Observation)Provides guide for interpretation of component result

                                                                  doco Documentation for this format