Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatus' vs 'http://paciowg.github.io/functional-status-ig/StructureDefinition/pacio-fsc' |
Error | StructureDefinition.version | Values for version differ: '4.0.0' vs '0.1.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreSmokingStatusProfile' vs 'FunctionalStatusCollection' |
Information | StructureDefinition.title | Values for title differ: 'US Core Smoking Status Observation Profile' vs 'PACIO Functional Status Collection' |
Information | StructureDefinition.date | Values for date differ: '2019-05-21T00:00:00+00:00' vs '2021-09-23T10:50:45-07:00' |
Warning | Observation | Elements differ in definition:
'The US Core Smoking Status Observation Profile is based upon the core FHIR Observation Resource and created to meet the USCDI Data Set 'Smoking status' requirements.'
'Measurements and simple assertions made about a patient, device or other subject.' |
Warning | Observation.extension | Elements differ in short:
'Additional content defined by implementations'
'Extension' |
Warning | Observation.extension | Elements differ in definition:
'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.'
'An Extension' |
Warning | Observation.basedOn | Elements differ in short:
'Fulfills plan, proposal or order'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.partOf | Elements differ in short:
'Part of referenced event'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.status | Elements differ in short:
'registered | preliminary | final | amended +'
'Should have the value 'final' when all the observatons are complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.' |
Error | Observation.status | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.category | Elements differ in short:
'Classification of type of observation'
'A second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code.' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Smoking Status'
'For a Post-Acute Care structured assessment resource such as an instrument or screen, use a LOINC code to identify the instrument/screen name or panel/section title to indicate the kind of assessment.' |
Error | Observation.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.subject | Elements differ in short:
'Who and/or what the observation is about'
'Should only reference a Patient resource.' |
Error | Observation.subject | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.focus | Elements differ in short:
'What the observation is about, when it is not about the subject of record'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.effective[x] | Elements differ in short:
'Clinically relevant time/time-period for observation'
'Clinical relevant time for an assessment such as functional assessments performed with structured evaluation tools is the time the evaluation occurs, i.e., when the clinician obtains the answers entered in the tool. However, the only timing available may be when then tool is completed by the clinician. That timing is generally documented as a point in time (dateTime).' |
Warning | Observation.effective[x] | Elements differ in definition:
'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
'Clinical relevant time for an assessment such as functional assessments performed with structured evaluation tools is the time the evaluation occurs, i.e., when the clinician obtains the answers entered in the tool. However, the only timing available may be when then tool is completed by the clinician. That timing is generally documented as a point in time (dateTime).' |
Warning | Observation.effective[x] | Elements differ in comments:
'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing] datatype which allow the measurement to be tied to regular life events.'
'The use of effective[x] and dateTime versus Period is subject to implementer workflow and needs. In most situations, an observation is considered as a point in time, even if the assessment occurred over a period of time. Period is included in this implementation guide to provide additional flexibility for specific use cases. However, it is expected most observations will be recorded using DateTime. Furthermore, any retrieval of information should return the relevant if DateTime is requested, even if the original observation was recorded as a period. Some implementers may choose to use additional functions in there retrieves to 'normalize' intervals, as is done in Clinical Quality Language (CQL).' |
Warning | Observation.issued | Elements differ in short:
'Date/Time this version was made available'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.performer | Elements differ in short:
'Who is responsible for the observation'
'The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization.' |
Warning | Observation.value[x] | Elements differ in short:
'Actual result'
'If used, should use the CodeableConcept datatype whenever possible to provide a suitable code to define the concept for the observation data. When capturing a collection of related observations, typically this field is not used. If the outcome of an assessment includes one or more summary scores, leave this field unused and use the 'hasMember' field to point to one or more Observation resources with each of which has a score provided in the 'value' field.' |
Warning | Observation.dataAbsentReason | Elements differ in short:
'Why the result is missing'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.interpretation | Elements differ in short:
'High, low, normal, etc.'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.bodySite | Elements differ in short:
'Observed body part'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.method | Elements differ in short:
'How it was done'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.specimen | Elements differ in short:
'Specimen used for this observation'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.device | Elements differ in short:
'(Measurement) Device'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.referenceRange | Elements differ in short:
'Provides guide for interpretation'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.hasMember | Elements differ in short:
'Related resource that belongs to the Observation group'
'Each functional status observation in the collection.' |
Error | Observation.hasMember | Elements differ in definition for mustSupport:
'false'
'true' |
Warning | Observation.derivedFrom | Elements differ in short:
'Related measurements the observation is made from'
'Should point back to the QuestionnaireResponse that this resource is derived from.' |
Error | Observation.derivedFrom | Elements differ in definition for mustSupport:
'false'
'true' |
Error | Observation.derivedFrom | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse]]) |
Warning | Observation.component | Elements differ in short:
'Component results'