ValueSet Comparison between http://hl7.org/fhir/us/core/ValueSet/us-core-smoking-status-observation-codes vs http://hl7.org/fhir/us/pacio-splasch/ValueSet/SPLASCHHearingObservationVS

Messages

ErrorValueSet.urlValues for url differ: 'http://hl7.org/fhir/us/core/ValueSet/us-core-smoking-status-observation-codes' vs 'http://hl7.org/fhir/us/pacio-splasch/ValueSet/SPLASCHHearingObservationVS'
ErrorValueSet.versionValues for version differ: '4.0.0' vs '0.1.0'
InformationValueSet.nameValues for name differ: 'USCoreSmokingStatusObservationCodes' vs 'SPLASCHHearingObservationVS'
InformationValueSet.titleValues for title differ: 'US Core Smoking Status Observation Codes' vs 'Hearing Observation'
InformationValueSet.dateValues for date differ: '2019-05-21' vs '2022-05-04T12:01:11-04:00'
InformationValueSet.publisherValues for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 Patient Care Working Group'
InformationValueSet.copyrightValues for copyright differ: 'This material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc' vs 'This CodeSystem is not copyrighted.'

Metadata

NameValueComments
.compose.inactive
    .compose.lockedDate
      .copyrightThis material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, IncThis CodeSystem is not copyrighted.
      • Values Differ
      .date2019-05-212022-05-04T12:01:11-04:00
      • Values Differ
      .descriptionThe US Core Smoking Status Observation Codes Value Set is a 'starter set' of concepts to capture smoking status.SPLASCH hearing observation profile: codes representing hearing questions that are answered by the ValueSet SPLASCHHearingObservationValueCodeableConceptVS
      • Values Differ
      .experimental
        .immutable
          .jurisdiction
            ..jurisdiction[0]urn:iso:std:iso:3166#US
              .nameUSCoreSmokingStatusObservationCodesSPLASCHHearingObservationVS
              • Values Differ
              .publisherHL7 International - US Realm Steering CommitteeHL7 Patient Care Working Group
              • Values Differ
              .purpose
                .statusactive
                  .titleUS Core Smoking Status Observation CodesHearing Observation
                  • Values Differ
                  .urlhttp://hl7.org/fhir/us/core/ValueSet/us-core-smoking-status-observation-codeshttp://hl7.org/fhir/us/pacio-splasch/ValueSet/SPLASCHHearingObservationVS
                  • Values Differ
                  .version4.0.00.1.0
                  • Values Differ

                  Definition

                  ItemPropertyValueComments
                  .includehttp://loinc.org
                    ..Concept72166-2Version: Tobacco smoking status NHIS
                    • Removed this Concept
                    ..Concept95744-9Version: Hearing ability to hear during assessment period [CMS Assessment]
                    • Added this Concept
                    ..Concept54599-6Version: Hearing aid used during assessment period [CMS Assessment]
                    • Added this Concept
                    ..Concept94900-8Version: Need for and availability of a hearing aid [CMS Assessment]
                    • Added this Concept
                    ..Concept67467-1Version: In which ear(s) do you have a hearing difficulty?
                    • Added this Concept
                    ..Concept67242-8Version: Do you hear better in one ear than the other [PhenX]
                    • Added this Concept
                    .includehttp://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS
                    • Added Include
                    .includehttp://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS
                    • Added Include

                    Expansion

                    SystemCodeDisplayComments
                    .http://loinc.org72166-2Tobacco smoking status NHIS
                    • Removed from expansion
                    .http://loinc.org95744-9Hearing ability to hear during assessment period [CMS Assessment]
                    • Added to expansion
                    .http://loinc.org54599-6Hearing aid used during assessment period [CMS Assessment]
                    • Added to expansion
                    .http://loinc.org67235-2Does the examinee have hearing aids that cannot be removed [PhenX]
                    • Added to expansion
                    .http://loinc.org94900-8Need for and availability of a hearing aid [CMS Assessment]
                    • Added to expansion
                    .http://loinc.org67467-1In which ear(s) do you have a hearing difficulty?
                    • Added to expansion
                    .http://loinc.org67242-8Do you hear better in one ear than the other [PhenX]
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS91375-6Hearing threshold Ear - left --250 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89024-4Hearing threshold Ear - left --500 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS91379-8Hearing threshold Ear - left --750 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89016-0Hearing threshold Ear - left --1000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS91373-1Hearing threshold Ear - left --1500 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89018-6Hearing threshold Ear - left --2000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89020-2Hearing threshold Ear - left --3000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89022-8Hearing threshold Ear - left --4000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS91377-2Hearing threshold Ear - left --5000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89026-9Hearing threshold Ear - left --6000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89028-5Hearing threshold Ear - left --8000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS91374-9Hearing threshold Ear - right --250 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89025-1Hearing threshold Ear - right --500 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS91378-0Hearing threshold Ear - right --750 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89017-8Hearing threshold Ear - right --1000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS91372-3Hearing threshold Ear - right --1500 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89019-4Hearing threshold Ear - right --2000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89021-0Hearing threshold Ear - right --3000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89023-6Hearing threshold Ear - right --4000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS91376-4Hearing threshold Ear - right --5000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89027-7Hearing threshold Ear - right --6000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHPureToneThresholdAudiometryPanelCS89029-3Hearing threshold Ear - right --8000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98419-5Diagnostic audiology test performed
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98480-7Auditory brainstem response panel
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98481-5Auditory brainstem response threshold Ear - left --click
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98482-3Auditory brainstem response threshold Ear - right --click
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89024-4Hearing threshold Ear - left --500 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89025-1Hearing threshold Ear - right --500 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89016-0Hearing threshold Ear - left --1000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89017-8Hearing threshold Ear - right --1000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89018-6Hearing threshold Ear - left --2000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89019-4Hearing threshold Ear - right --2000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89020-2Hearing threshold Ear - left --3000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89021-0Hearing threshold Ear - right --3000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89022-8Hearing threshold Ear - left --4000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS89023-6Hearing threshold Ear - right --4000 Hz
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98421-1Hearing loss type Ear - left
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98426-0Hearing loss type Ear - right
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98425-2Hearing loss configuration Ear - left
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98430-2Hearing loss configuration Ear - right
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98422-9Hearing loss degree Ear - left
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98427-8Hearing loss degree Ear - right
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98424-5Hearing loss degree.max Ear - left
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98429-4Hearing loss degree.max Ear - right
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98423-7Hearing loss degree.min Ear - left
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98428-6Hearing loss degree.min Ear - right
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98420-3Audiology Comment Narrative
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98431-0Diagnostic audiology follow-up recommendation
                    • Added to expansion
                    .http://hl7.org/fhir/us/pacio-splasch/CodeSystem/SPLASCHDiagnosticAudiologyResultsPanelCS98432-8Reason diagnostic audiology assessment not performed
                    • Added to expansion