PACIO Functional Status Implementation Guide
0.1.0 - CI Build

PACIO Functional Status Implementation Guide - Local Development build (v0.1.0). See the Directory of published versions

Extension: DevicePatientUsed - Detailed Descriptions

Definitions for the device-patient-used extension.

1. Extension
Definition

Associated with the Funcational Status Collection profile to point to a record indicating what healthcare-related assistive device was used by a patient during a functional status assessment. This extension leverages the DeviceUseStatement resource instead of Device resource so as to indicate appropriately a record of assistive device usage by a patient.

Control0..* This element is affected by the following invariants: ele-1
InvariantsDefined on this element
ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (: extension.exists() != value.exists())
2. Extension.id
Definition

Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

Control0..1
Typestring
3. Extension.extension
Definition

An Extension

Control0..0
TypeExtension
InvariantsDefined on this element
ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (: extension.exists() != value.exists())
SlicingThis element introduces a set of slices on Extension.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • value @ url
4. Extension.url
Definition

Source of the definition for the extension code - a logical name or a URL.

Control1..1
Typeuri
Comments

The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension.

Fixed Valuehttp://paciowg.github.io/functional-status-ig/StructureDefinition/device-patient-used
5. Extension.value[x]
Definition

Value of extension - must be one of a constrained set of the data types (see Extensibility for a list).

Control0..1
TypeReference(UseOfDevice)
[x] NoteSee Choice of Data Types for further information about how to use [x]
InvariantsDefined on this element
ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count()))